Micro Switch
"S"


Best suited
for a wide variety of uses, such as office equipment, telecommunication
equipment and audio equipment |
HIGH
QUALITY AND LOW PRICE Embodying the so-called "lighter, thinner, shorter
and smaller" product concept, TORX MICRO SWITCHES have realized
micro-order precision, product miniaturization and cost reduction
with our fully automated production lines
GOOD SNAP ACTION Leaf springs undergo no bending work load in the
production process. So, good snap action ensured and spring characteristics
can be utilized to the full. All these innovations have contributed
to the high performance and great reliability of TORX MICRO SWITCHES
VERIETY OF TERMINALS Straight terminal, Lead
terminal
RATING
TYPE (contact) |
OF (MAX) |
RATING
|
|
|
|
|
5A, 125VAC 4A, 30VDC |
|
3A, 30VDC |
|
|
|
|
|
* OF is max of button type. |
|
ITEM |
PERFORMANCE DATA |
|
Service life Mechanical |
Over 5,000,000 cycles Switching frequency: 60 cycles/min., O.T. 100%) |
Service life Electrical Standard
type |
Standard OF: Over 100,000
cycles (rated load) Switching frequency: 20 cycles/min.,
O.T. 100%) |
|
Service life Electrical Micro load
type |
Over 500,000 cycles (rated load) Switching frequency: 20 cycles/min., O.T. 100%) |
|
Insulation resistance |
Over 100MW When
measured with 500VDC insulation resistance meter) |
|
With-stand Voltage |
Between non-consecutive terminal xx |
|
Between each terminal and discharged
metal parts |
Between each terminal an earth
|
|
|
1,000VAC, 50/60Hz, 1mn. xx xxx
|
1,500VAC, 50/60Hz, 1min xx xxx
|
1,500VAC, 50/60Hz, 1min xx xxx
|
|
|
Vibration resistance |
Multi amplitude 1.5mm, 10-55Hz Less than 1 msec. for contact opening) |
|
Impact resistance |
50G less than 1
msec. for contacting opening |
|
Contact resistance |
less than 15mW (initial
value) |
|
Allowable operation speed (non-load) |
0.1mm/s-0.5m/s (for push button
type) |
|
Maximum switching frequency |
300 cycles/min, mechanical |
|
Operating temperature and humidity
ranges |
-25 degree-C to 80 degree-C (not
frozen), less than 85% RH |
|
|
|
Operating Characteristics |
|
Standard Type |
Low capacity Type |
|
|
Operating Force MAX (g) |
|
|
Release Force MIN(g) |
|
|
Pre-travel MAX(mm) |
0.5 |
|
Over-travel MIN(mm) |
0.5 |
|
Movement Differential MAX (mm) |
0.1 |
|
Operating Position (mm) |
8.4±0.5 |
|
|
Operating Characteristics |
|
Standard Type |
Low capacity Type |
|
|
Operating Force MAX (g) |
|
|
Release Force MIN(g) |
|
|
Pre-travel MAX(mm) |
2.5 |
|
Over-travel MIN(mm) |
1.2 |
|
Movement Differential MAX (mm) |
0.8 |
|
Operating Position (mm) |
8.8±0.8 |
|
|
|